Over 20+ years experience with Vokera Boilers
0203 695 3137
Boiler Repairs R Us are experienced in handling all types of Vokera Boilers. We can also assist with all gas, condensing, combi boiler installations and upgrades. All our plumbers are Gas Safe Registered so you can be assured all our work is carried out within the required regulations. So for complete customer satisfaction call us on 0203 695 3137 to get your Vokera Boilers repaired today!
Trusted, reliable boilers repair & install specialists.
Get pricing and book repairCommon Vokera faults, fault codes, safe checks, and when to call a Gas Safe engineer.
We specialise in Vokera boiler repairs across London.
Gas Safe registered engineers for safe diagnosis, repair and testing.
24/7 availability with London wide call handling and booking.
Seeing A01, A04 or A06? No heating or hot water? Tell us the fault code, model and postcode and we will advise the quickest safe next step.
📞 Call 0203 695 3137
Request Call Back
Fast triage: Vokera model (Easi-Flo, Mynute, Vision, Compact, Linea, Excell, Synergy), fault code, postcode, and whether other gas appliances work for ignition faults.
Smell gas? Do not touch anything. Do not use switches. Open windows, leave the property, and call the National Gas Emergency Line: 0800 111 999.
Carbon monoxide alarm sounding? Get everyone out immediately and call 999. Learn more about carbon monoxide safety.
No gas smell, no alarm? Your boiler may have locked out as a safety precaution. Try the quick checks below.
Jump to: Fault Codes · A04 Fault · Pressure · Frozen Condensate · Repair or Replace
These take 60 seconds and solve a surprising number of lockouts:
Note: Vokera uses A codes on most models. If unsure, call us and we will help you identify your specific code.
| Code | What It Means | What To Do |
|---|---|---|
| A01 | Ignition failure (no flame established) | Check gas supply and other appliances. Check condensate pipe in freezing weather. If still locked out, call an engineer. |
| A04 | Ignition lockout (multiple failed attempts) | Check gas supply and condensate pipe. If still locked out, call an engineer. |
| A06 | Low water pressure | Top up pressure using filling loop (see below). If it drops again within days, call an engineer. |
| A08 | Flame lost during operation | Reset once. If it happens again, call an engineer. |
| A10 | Flue sensor fault | Call an engineer. |
| A12 | No circulation detected | Check radiators are getting hot. If circulation seems poor, call an engineer. |
| A03 | Fan fault | Call an engineer. |
| A14 | Overheat lockout | Do not repeatedly reset. Call an engineer. |
What is happening: The boiler has attempted to ignite multiple times and failed, triggering a lockout. This is one of the most common Vokera fault codes.
Common causes: Frozen condensate pipe (winter), gas supply interruption, faulty ignition electrode or lead, blocked or damaged flue, gas valve fault.
What to try: Check if your gas hob or other gas appliances work. In freezing weather, check the condensate pipe for ice. If gas supply is fine but the boiler will not ignite, call an engineer.
Note: A04 often appears alongside or after A01 on Vokera boilers. Both indicate ignition problems.
What is happening: The boiler is not detecting adequate water flow through the heat exchanger.
Common causes: Pump failure, airlocks in the system, blocked or restricted pipework, sludge build up, faulty flow sensor.
What to try: Check if radiators are heating. If some are cold at the bottom, there may be sludge. If the pump is not running, call an engineer. A power flush may be needed if sludge is suspected.
What is happening: System pressure has dropped below the minimum operating level.
Common causes: Small leak in the system, recently bled radiators, pressure relief valve discharge, expansion vessel needs recharging.
What to try: Top up pressure using the filling loop (see below). If pressure drops again within days, there may be a leak. Read our pressure guide for step by step instructions.
If you are not comfortable using the filling loop, stop and call a Gas Safe engineer.
Do not remove the boiler casing. If you cannot locate the filling loop easily, call an engineer.
Do not exceed 2.0 bar. If you overfill, stop and call an engineer.
If you need to top up frequently (more than once a month), there is likely a leak. Call us for a diagnosis.
In freezing weather, a frozen condensate pipe is one of the most common causes behind A01 and A04 lockouts on Vokera boilers. This is often safe to resolve with the steps below. If you are unsure, or the boiler will not restart, call an engineer.
Signs: Boiler locked out with A01 or A04, freezing temperatures outside, gurgling sound when boiler tries to start.
What to do:
Full instructions: Frozen condensate pipe guide.
If it keeps happening, we can reroute the pipe internally or add insulation to reduce future freezing.
Hard water, older pipework, and winter weather make certain faults more likely in London properties:
We repair all Vokera gas boiler models including:
We carry common Vokera parts and can source others. Parts availability is generally good.
Ignition failures (A01/A04): The most common Vokera repair. Often caused by worn electrodes, faulty ignition components, gas valve issues, or a frozen condensate pipe in winter.
Fan faults (A03): Fan not running at correct speed or failing to prove to the PCB.
Diverter valve sticking: Hot water works but radiators stay cold, or vice versa. Common on models over 8 years old.
PCB failure: Random lockouts, display glitches, or complete failure.
Pump failure: No circulation (A12), overheating, radiators not heating evenly.
Heat exchanger blockage: Kettling noises, overheating, reduced efficiency. See our guide to boiler noises.
Vokera boilers typically last 10 to 15 years with proper maintenance. If yours is approaching that age and needs a major repair (heat exchanger, PCB, pump), replacement may be more cost effective.
We give honest advice either way. Read more: Repair or replace? An engineer’s guide.
If you decide on a new boiler: New boiler installation.
If your Vokera keeps showing A04 even after the condensate pipe is clear, it may be worn ignition components or a fault that needs testing. London is a hard water area and over time debris can restrict circulation. A power flush clears the system and can improve overall reliability. Learn more about power flushing.
Annual servicing keeps your Vokera running efficiently and helps maintain warranty terms. We service Vokera models and provide a clear report after each visit.
We recommend servicing in late summer or early autumn, before the heating season. Book your boiler service.
Tenants: Your landlord is usually responsible for boiler repairs. Contact them first and keep written records, especially if you have no heating or hot water.
Landlords: Stay compliant with our Gas Safety Certificate (CP12) service. See our full London landlord checklist covering gas safety, EPCs, and boiler maintenance.
We repair Vokera boilers across all London boroughs. See our London coverage area or find your local page:
Gas Safe engineers available across London. Speak to our team for safe next steps.