Call us today Mobile navigation

Boiler Repairs Viesmann Boiler Repairs

Viessmann Boiler Repairs London

Over 20+ years experience with Viessmann Boilers

24 hour service
Insurance approved
All parts guaranteed for a year
90% repaired on the same day

0203 695 3137


How we can assist with your Viessmann Boilers

  • Emergency Boiler Repairs
  • Boiler Service
  • Landlord Safety Certificates
  • New Boilers Installations
  • Leaking & Noisy Boilers
  • Power Flushes

Boiler Repairs R Us are experienced in handling all types of Viessmann Boilers. We can also assist with all gas, condensing, combi boiler installations and upgrades. All our plumbers are Gas Safe Registered so you can be assured all our work is carried out within the required regulations. So for complete customer satisfaction call us on 0203 695 3137 to get your Viessmann Boilers repaired today!


Join 1,000’s of happy customers in London!

Trusted, reliable boilers repair & install specialists.

Get pricing and book repair  

Viessmann Boilers and Boiler Repairs R Us

Viessmann Boiler Repair Help Centre

Common Viessmann faults, fault codes, safe checks, and when to call a Gas Safe engineer.

We specialise in Viessmann boiler repairs across London.

Gas Safe registered engineers for safe diagnosis, repair and testing.

24/7 availability with London wide call handling and booking.

Viessmann Boiler Repair London (Gas Safe)

Seeing F4, F2 or a pressure warning? No heating or hot water? Tell us the fault code, model and postcode and we will advise the quickest safe next step.

📞 Call 0203 695 3137
Request Call Back

Fast triage: Vitodens model (050-W, 100-W, 200-W), fault code, postcode, and whether other gas appliances work for ignition faults.

⚠️ Safety First

Smell gas? Do not touch anything. Do not use switches. Open windows, leave the property, and call the National Gas Emergency Line: 0800 111 999.

Carbon monoxide alarm sounding? Get everyone out immediately and call 999. Learn more about carbon monoxide safety.

No gas smell, no alarm? Your boiler may have locked out as a safety precaution. Try the quick checks below.

Jump to: Fault Codes · F4 · Pressure · Frozen Condensate · Repair or Replace

Quick Checks Before You Call Anyone

These take 60 seconds and solve a surprising number of lockouts:

  1. Check boiler pressure: Aim for 1.0 to 1.5 bar when cold. More detail in our complete pressure guide.
  2. Note the fault code: Write it down before you reset. Viessmann commonly shows faults like F4 or F2.
  3. Check electrics: Boiler fused spur on, no tripped breakers.
  4. Check thermostat and timer: Confirm demand is on and set above room temperature.
  5. Freezing weather? The condensate pipe may be frozen (see below).
  6. Reset once only: Use the reset button once, wait 60 seconds. If it locks out again, stop and call an engineer.

Viessmann Fault Codes

Note: Viessmann fault codes can vary by model and controller. If your code is different, call us with the exact code and model and we will advise the safest next step.

Common Viessmann fault codes and what to do
Code What It Means What To Do
F4 Ignition failure / no flame detected Check gas supply and whether other gas appliances work. Check condensate pipe in freezing weather. If it returns, call an engineer.
F2 Overheat protection triggered Do not keep resetting. Call an engineer to check circulation and safety controls.
Low pressure System pressure too low Top up pressure to 1.0 to 1.5 bar. If it drops again within days, call an engineer.
Fan / airflow Airflow proving or fan issue Call an engineer. Do not attempt DIY on flues.
Sensor fault Temperature or system sensor issue Reset once. If it returns, call an engineer for testing.
Circulation / flow Restricted flow or pump related issue Check radiators are warming evenly. If it returns, call an engineer.

F4: Ignition Failure

What is happening: The boiler is attempting to ignite but cannot establish a stable flame, so it locks out.

Common causes: Gas supply interruption, frozen condensate pipe, ignition components, airflow or flue issues, or a control fault that needs testing.

What to try: Check if your gas hob works. In freezing weather check the condensate pipe for ice. Reset once only. If F4 returns, call an engineer.

Low Pressure

If pressure is below 1 bar, top up to 1.0 to 1.5 bar. Step by step help: pressure guide.

How to Top Up Pressure (Viessmann)

If you are not comfortable using the filling loop, stop and call a Gas Safe engineer.

Do not remove the boiler casing. If you cannot locate the filling loop easily, call an engineer.

  1. Locate the filling loop (usually underneath the boiler, a braided silver hose with one or two valves).
  2. Ensure the boiler is off and cool.
  3. Open the valves slowly, a quarter turn at a time.
  4. Watch the pressure rise to between 1.0 and 1.5 bar.
  5. Close both valves fully.
  6. Switch the boiler back on.

Do not exceed 2.0 bar. If you overfill, stop and call an engineer.

If you need to top up frequently, there is likely a leak or component issue. Book a diagnosis.

Frozen Condensate Pipe (Winter)

In freezing weather, a frozen condensate pipe is a common cause of ignition lockouts like F4.

  1. Locate the condensate pipe (white or grey plastic pipe running to an outside drain).
  2. Pour warm water (not boiling) over the frozen section.
  3. Reset the boiler once thawed.

Full instructions: frozen condensate pipe guide.

Why These Faults Are Common in London Homes

  • Hard water: limescale and magnetite sludge reduce flow and can contribute to overheat trips.
  • Winter snaps: external condensate pipes freeze and cause ignition lockouts.
  • Older systems: pressure drops are more common after radiator bleeding or where there are small leaks.

Viessmann Models We Repair

  • Vitodens 050-W: combi and system
  • Vitodens 100-W: widely installed combi and system
  • Vitodens 200-W: higher specification models
  • Older Viessmann installations: common across London homes

🔧 F2 Overheat or Cold Radiators?

If you are seeing overheat issues or radiators are cold at the bottom, restricted circulation from sludge can contribute. A power flush clears debris and improves flow. Power flush guide.

Repair or Replace?

Viessmann boilers typically last 10 to 15 years with proper maintenance. If yours is approaching that age and needs a major repair (PCB, fan, heat exchanger), replacement may be more cost effective.

Read: Repair or replace? and New boiler installation.

Viessmann Servicing

Annual servicing reduces breakdown risk and protects performance. Book: boiler servicing.

Renting? Landlords: Check This

Landlords: Gas Safety Certificate (CP12) and our London landlord checklist.

London Wide Coverage

We repair Viessmann boilers across all London boroughs.

We Also Repair These Brands

This guide is written and reviewed by Gas Safe registered engineers with over 20 years experience repairing Viessmann boilers across London. Last updated December 2025.

Book Your Viessmann Repair

Gas Safe engineers available across London. Speak to our team for safe next steps.

📞 Call 0203 695 3137
Request Call Back

Related Services and Guides